12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970 |
- #!/usr/bin/python
- # Author: Zion Orent <zorent@ics.com>
- # Copyright (c) 2015 Intel Corporation.
- #
- # Permission is hereby granted, free of charge, to any person obtaining
- # a copy of this software and associated documentation files (the
- # "Software"), to deal in the Software without restriction, including
- # without limitation the rights to use, copy, modify, merge, publish,
- # distribute, sublicense, and/or sell copies of the Software, and to
- # permit persons to whom the Software is furnished to do so, subject to
- # the following conditions:
- #
- # The above copyright notice and this permission notice shall be
- # included in all copies or substantial portions of the Software.
- #
- # THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND,
- # EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF
- # MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND
- # NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE
- # LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION
- # OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION
- # WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.
-
- import time, sys, signal, atexit
- import pyupm_mhz16 as upmMhz16
-
- # Instantiate a MHZ16 serial CO2 sensor on uart 0.
- # This example was tested on the Grove CO2 sensor module.
- myCO2 = upmMhz16.MHZ16(0)
-
-
- ## Exit handlers ##
- # This stops python from printing a stacktrace when you hit control-C
- def SIGINTHandler(signum, frame):
- raise SystemExit
-
- # This function lets you run code on exit,
- # including functions from myCO2
- def exitHandler():
- print "Exiting"
- sys.exit(0)
-
- # Register exit handlers
- atexit.register(exitHandler)
- signal.signal(signal.SIGINT, SIGINTHandler)
-
-
- # make sure port is initialized properly. 9600 baud is the default.
- if (not myCO2.setupTty(upmMhz16.cvar.int_B9600)):
- print "Failed to setup tty port parameters"
- sys.exit(0)
-
- print ("Make sure that the sensor has had "
- "at least 3 minutes to warm up\n"
- "or you will not get valid results.\n"
- "The temperature reported is not the ambient temperature,\n"
- "but rather the temperature of the sensor elements.")
-
- time.sleep(1)
-
- while(1):
- if (not myCO2.getData()):
- print "Failed to retrieve data"
- else:
- outputStr = ("CO2 concentration: {0} PPM, "
- "Temperature (in C): {1}".format(
- myCO2.getGas(), myCO2.getTemperature()))
- print outputStr
-
- time.sleep(2)
|